FrequencyDC~6GHz, Adjustable attenuation10~70dB, step10dB, Power Capacity2W, N-K
Broadband, adjustable attenuation value.
Parameters | Min | Typical | Max | Units |
Frequency | DC | ~ | 6 | GHz |
Adjustable attenuation | 10 | ~ | 70 | dB |
step | 10 | dB | ||
VSWR | 1.85 |
Power Capacity | 2W Design assurance |
Impedance | 50Ω |
Connector | N -K |
Product shell material | Aluminum |
Operation Temp. | -20~+85℃ Design assurance |
Other | Manually adjustable |
Attenuation | Attenuation accuracy | |
1 | 10-30dB | ±0.9dB |
2 | 40-70dB | ±1.5dB |
1. When installing attenuators, it is necessary to consider sufficient heat dissipation space and avoid installing them next to equipment with high heat output, otherwise the power capacity will decrease;
2. Small power attenuators do not have input and output directions, nor do they indicate directions. When high-power attenuators have input and output port markings, they must be connected to the equipment in the specified direction, otherwise the attenuator may burn out.
Frequency(MHz) | S11 VSWR | 10dB | 20dB | 30dB | 60dB | |
0.01 | 1.04 | -9.95 | -19.9 | -29.97 | -59.77 | |
643 | 1.05 | -10.13 | -20.08 | -30.15 | -60.08 | |
1286 | 1.08 | -10.19 | -20.15 | -30.23 | -60.22 | |
1929 | 1.08 | -10.25 | -20.22 | -30.29 | -60.25 | |
2571 | 1.07 | -10.29 | -20.26 | -30.34 | -60.33 | |
3214 | 1.08 | -10.35 | -20.3 | -30.4 | -60.45 | |
3857 | 1.06 | -10.37 | -20.35 | -30.49 | -60.58 | |
4500 | 1.1 | -10.44 | -20.41 | -30.58 | -60.73 | |
5143 | 1.3 | -10.49 | -20.44 | -30.65 | -60.81 | |
5786 | 1.39 | -10.53 | -20.47 | -30.71 | -60.93 | |
6429 | 1.25 | -10.58 | -20.87 | -30.8 | -61.58 | |
7071 | 1.12 | -10.71 | -20.76 | -31.01 | -61.78 | |
7714 | 1.07 | -10.71 | -20.72 | -31.13 | -62.09 | |
8357 | 1.39 | -10.69 | -20.82 | -31.13 | -63.15 | |
9000 | 1.74 | -11.09 | -21.51 | -31.79 | -64.85 |