FrequencyDC~6GHz, Attenuation50dB, 500W, 50Ω, N-JK
Parameters | Min | Typical | Max | Units |
Frequency | DC | ~ | 6 | GHz |
Attenuation | 48.5 | 50 | 51.5 | dB |
VSWR | 1.3 |
Power | 500W Design assurance |
Impedance | 50Ω |
Connector | N -JK |
Connector material | Stainless steel |
Surface | Black |
Product shell material | Aluminum |
Work Temp. | -40~+85℃ Design assurance |
Other | In Port N-J |
1. When installing attenuators, it is necessary to consider sufficient heat dissipation space and avoid installing them next to equipment with high heat output, otherwise the power capacity will decrease;
2. Small power attenuators do not have input and output directions, nor do they indicate directions. When high-power attenuators have input and output port markings, they must be connected to the equipment in the specified direction, otherwise the attenuator may burn out.
Frequency GHz | S11 VSWR | S22 VSWR | S12 IL (dB) |
0.01 | 1.01 | 1.01 | -50.17 |
0.71 | 1.02 | 1.01 | -50.21 |
1.43 | 1.01 | 1.02 | -50.5 |
2.14 | 1.09 | 1.02 | -50.6 |
2.86 | 1.11 | 1.04 | -50.64 |
3.57 | 1.05 | 1.05 | -50.61 |
4.29 | 1.09 | 1.08 | -50.47 |
5 | 1.09 | 1.1 | -50.28 |
5.71 | 1.14 | 1.12 | -50 |
6.43 | 1.13 | 1.06 | -49.63 |
7.14 | 1.1 | 1.03 | -49.19 |
7.86 | 1.19 | 1.01 | -48.82 |
8.57 | 1.24 | 1.03 | -48.28 |
9.29 | 1.18 | 1.1 | -47.43 |
10 | 1.09 | 1.09 | -46.25 |