FrequencyDC~6GHz, Attenuation40dB, Power500W, Impedance50Ω, N-JK
Parameters | Min | Typical | Max | Units |
Frequency | DC | ~ | 6 | GHz |
Attenuation | 38.9 | 40 | 41.1 | dB |
VSWR | 1.3 |
Power | 500W Design assurance |
Impedance | 50Ω |
Connector | N -JK |
Connector material | Stainless steel |
Surface | Black |
Product shell material | Aluminum |
Work Temp. | -40~+85℃ Design assurance |
1. When installing attenuators, it is necessary to consider sufficient heat dissipation space and avoid installing them next to equipment with high heat output, otherwise the power capacity will decrease;
2. Small power attenuators do not have input and output directions, nor do they indicate directions. When high-power attenuators have input and output port markings, they must be connected to the equipment in the specified direction, otherwise the attenuator may burn out.
Frequency(GHz) | S11 VSWR | S12 IL dB |
0.01 | 1.08 | -39.79 |
0.57 | 1.1 | -40.48 |
1.14 | 1.01 | -40.73 |
1.71 | 1.1 | -40.88 |
2.29 | 1.07 | -40.91 |
2.86 | 1.06 | -40.84 |
3.43 | 1.11 | -40.75 |
4 | 1.12 | -40.61 |
4.57 | 1.09 | -40.43 |
5.14 | 1.11 | -40.2 |
5.71 | 1.06 | -39.94 |
6.29 | 1.1 | -39.73 |
6.86 | 1.15 | -39.61 |
7.43 | 1.31 | -39.4 |
8 | 1.07 | -39.08 |