FrequencyDC~67GHz, Attenuation10dB, 2W, 50Ω, 1.85-JK
Broadband, small volume.
Parameters | Min | Typical | Max | Units |
Frequency | DC | ~ | 67 | GHz |
Attenuation | 8.9 | 10 | 11.5 | dB |
VSWR | 1.65 |
Power | 2W Design assurance |
Impedance | 50Ω |
Connector | 1.85-JK |
Connector material | Stainless steel |
Product shell material | Stainless steel |
Work Temp. | -40~+85℃ Design assurance |
1. When installing attenuators, it is necessary to consider sufficient heat dissipation space and avoid installing them next to equipment with high heat output, otherwise the power capacity will decrease;
2. Small power attenuators do not have input and output directions, nor do they indicate directions. When high-power attenuators have input and output port markings, they must be connected to the equipment in the specified direction, otherwise the attenuator may burn out.
Frequency(MHz) | S11 VSWR | S22 VSWR | S12 IL dB |
0.01 | 1.3 | 1.3 | -9 |
5 | 1.07 | 1.04 | -9.24 |
10 | 1.13 | 1.15 | -9.33 |
15 | 1.15 | 1.3 | -9.31 |
20 | 1.23 | 1.28 | -9.49 |
25 | 1.39 | 1.26 | -9.4 |
30 | 1.14 | 1.32 | -9.4 |
35 | 1.1 | 1.18 | -9.44 |
39 | 1.15 | 1.13 | -9.5 |
44 | 1.14 | 1.09 | -9.66 |
49 | 1.17 | 1.29 | -10.21 |
54 | 1.03 | 1.15 | -10.39 |
59 | 1.26 | 1.38 | -10.39 |
64 | 1.21 | 1.34 | -10.23 |
69 | 1.12 | 1.47 | -10.8 |