FrequencyDC~40GHz, Attenuation4dB, Power2W, 2.92-JK
Broadband, small volume.
Parameters | Min | Typical | Max | Units |
Frequency | DC | ~ | 40 | GHz |
Attenuation | 3 | 4 | 5 | dB |
VSWR | 1.25 |
Power | 2W Design assurance |
Impedance | 50Ω |
Connector | 2.92-JK |
Connector material | Stainless steel |
Work Temp. | -40~+85℃ Design assurance |
1. When installing attenuators, it is necessary to consider sufficient heat dissipation space and avoid installing them next to equipment with high heat output, otherwise the power capacity will decrease;
2. Small power attenuators do not have input and output directions, nor do they indicate directions. When high-power attenuators have input and output port markings, they must be connected to the equipment in the specified direction, otherwise the attenuator may burn out.
Frequency GHz | S11 VSWR | S22 VSWR | S12 IL (dB) |
0.01 | 1.02 | 1.01 | -3.33 |
3.21 | 1.01 | 1.02 | -3.49 |
6.43 | 1.02 | 1.01 | -3.57 |
9.64 | 1.04 | 1.02 | -3.58 |
12.86 | 1.1 | 1.09 | -3.62 |
16.07 | 1.04 | 1.05 | -3.62 |
19.29 | 1.06 | 1.04 | -3.65 |
22.5 | 1.03 | 1.02 | -3.71 |
25.71 | 1.07 | 1.08 | -3.77 |
28.93 | 1.08 | 1.12 | -3.87 |
32.14 | 1.09 | 1.12 | -3.98 |
35.36 | 1.03 | 1.07 | -4.08 |
38.57 | 1.05 | 1.1 | -4.23 |
41.79 | 1.18 | 1.05 | -4.37 |
45 | 1.28 | 1.14 | -4.54 |