FrequencyDC~4GHz, Attenuation40dB, 200W, 50Ω, N-JK
Broadband, high-power.
Parameters | Min | Typical | Max | Units |
Frequency | DC | ~ | 4 | GHz |
Attenuation | 39.1 | 40 | 40.9 | dB |
VSWR | 1.2 |
Power | 200W Design assurance |
Impedance | 50Ω |
Connector | N -JK |
Connector material | Stainless steel |
Surface | Black |
Product shell material | Aluminum |
Work Temp. | -40~+85℃ Design assurance |
Other | In Port N-J |
1. When installing attenuators, it is necessary to consider sufficient heat dissipation space and avoid installing them next to equipment with high heat output, otherwise the power capacity will decrease;
2. Small power attenuators do not have input and output directions, nor do they indicate directions. When high-power attenuators have input and output port markings, they must be connected to the equipment in the specified direction, otherwise the attenuator may burn out.
Frequency(GHz) | S11 VSWR | S12 Attenuation |
0.01 | 1.06 | -39.92 |
0.57 | 1.02 | -40.11 |
1.14 | 1.03 | -40.23 |
1.71 | 1.02 | -40.28 |
2.29 | 1.03 | -40.33 |
2.86 | 1.04 | -40.36 |
3.43 | 1.06 | -40.38 |
4 | 1.15 | -40.38 |
4.57 | 1.11 | -40.3 |
5.14 | 1.1 | -40.27 |
5.71 | 1.12 | -40.27 |
6.29 | 1.12 | -40.23 |
6.86 | 1.05 | -40.17 |
7.43 | 1.15 | -40.07 |
8 | 1.04 | -39.95 |