FrequencyDC~6GHz, Attenuation30±0.75dB, Power Capacity100W, Impedance50Ω, N-K
Parameters | Min | Typical | Max | Units |
Frequency | DC | ~ | 6 | GHz |
Attenuation | 30±0.75 | dB | ||
VSWR | 1.2 |
Power Capacity | 100W Design assurance |
Impedance | 50Ω |
Connector | N -K |
Connector material | Stainless steel |
Surface | Black |
Product shell material | Aluminum |
Operation Temp. | -40~+85℃ Design assurance |
1. When installing attenuators, it is necessary to consider sufficient heat dissipation space and avoid installing them next to equipment with high heat output, otherwise the power capacity will decrease;
2. Small power attenuators do not have input and output directions, nor do they indicate directions. When high-power attenuators have input and output port markings, they must be connected to the equipment in the specified direction, otherwise the attenuator may burn out.
Frequency(GHz) | S11 VSWR | S12 Attenuation |
0.01 | 1.02 | -29.67 |
0.57 | 1.03 | -29.85 |
1.14 | 1.05 | -29.91 |
1.71 | 1.04 | -29.91 |
2.29 | 1.03 | -29.9 |
2.86 | 1.03 | -29.9 |
3.43 | 1.04 | -29.93 |
4 | 1.05 | -29.96 |
4.57 | 1.08 | -30 |
5.14 | 1.11 | -30.04 |
5.71 | 1.14 | -30.07 |
6.29 | 1.13 | -30.11 |
6.86 | 1.11 | -30.14 |
7.43 | 1.12 | -30.18 |
8 | 1.15 | -30.23 |