FrequencyDC~6GHz, Adjustable attenuation1~90dB, step1dB, 2W, 50Ω, N-F
Broadband, adjustable attenuation value.
Parameters | Min | Typical | Max | Units |
Frequency | DC | ~ | 6 | GHz |
Adjustable attenuation | 1 | ~ | 90 | dB |
step | 1 | dB | ||
VSWR | 1.85 |
Power Capacity | 2W Design assurance |
Impedance | 50Ω |
Connector | N -F |
Product shell material | Aluminum |
Operation Temp. | -20~+85℃ Design assurance |
Other | Manual knob adjustment |
Attenuation | Attenuation accuracy | |
1 | 1- 10dB | ±0.6dB |
2 | 11-60dB | ±0.9dB |
3 | 61-70dB | ±1.5dB |
4 | 71-90dB | ±2.5dB |
1. When installing attenuators, it is necessary to consider sufficient heat dissipation space and avoid installing them next to equipment with high heat output, otherwise the power capacity will decrease;
2. Small power attenuators do not have input and output directions, nor do they indicate directions. When high-power attenuators have input and output port markings, they must be connected to the equipment in the specified direction, otherwise the attenuator may burn out.